护理领域人工智能应用态度量表的汉化及信效度检验
作者:
作者单位:

作者简介:

女,本科,主管护师

通讯作者:

基金项目:

中国人民解放军东部战区总医院科技创新项目(2023YYHLZX199)


Translation and validation of the Attitude Scale towards the Use of Artificial Intelligence Technologies in Nursing
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    目的 汉化护理领域人工智能应用态度量表(Attitude Scale towards the Use of Artificial Intelligence Technologies in Nursing,ASUAITIN)并在护理人员中检验其信效度。方法 遵循Brislin翻译模式对ASUAITIN进行翻译、文化调适及预调查,形成中文版ASUAITIN,并在530名在职护士中验证量表的信效度。结果 中文版ASUAITIN有消极和积极态度2个维度共15个条目。总量表Cronbach′s α系数为0.929,消极和积极态度维度分别为0.950和0.962;分半信度系数为0.970,重测信度系数为0.645;条目水平的内容效度指数为0.833~1.000,全体一致内容效度指数为0.867,平均内容效度指数为0.979。探索性因子分析共提取2个特征值>1的因子,累计方差贡献率85.591%。验证性因子分析显示χ2/df=2.735、RMSEA=0.081、GFI=0.892、CFI=0.951、NFI=0.925、IFI=0.951、TLI=0.942、AGFI=0.854;平均提取方差为0.665,组合信度为0.967。结论 中文版ASUAITIN信效度良好,可用于评估我国护理人员对人工智能应用的态度。

    Abstract:

    Objective To translate and culturally adapt the Attitude Scale towards the Use of Artificial Intelligence Technologies in Nursing (ASUAITIN) into Chinese and validate its psychometric properties among nurses. Methods Following Brislin′s translation model, the ASUAITIN underwent forward-backward translation, cultural adaptation, and pilot testing to form the Chinese version. A convenience sample of 530 registered nurses was recruited to evaluate the scale′s reliability and validity. Results The Chinese ASUAITIN comprised 15 items across two dimensions:negative attitudes and positive attitudes.The overall Cronbach′s α coefficient was 0.929, with subscale coefficients of 0.950 (negative attitudes) and 0.962 (positive attitudes). Split-half reliability was 0.970, and test-retest reliability was 0.907.Item-level content validity indices (I-CVI) ranged from 0.833 to 1.000, with a universal agreement CVI of 0.867 and a scale-level average CVI of 0.979.Exploratory factor analysis extracted two factors with eigenvalues >1, accounting for 85.591% of the cumulative variance. The confirmatory factor analysis showed the fit indices:χ2/df=2.735,RMSEA=0.081, GFI=0.892, CFI=0.951, NFI=0.925, IFI=0.951, TLI=0.942, AGFI=0.854. The average variance extracted was 0.665, and the composite reliability was 0.967. Conclusion The Chinese version of the ASUAITIN demonstrates robust reliability and validity, justifying its use as a valid tool to assess nurses′ attitudes toward AI applications in clinical practice.

    参考文献
    相似文献
    引证文献
引用本文

王嫄嫄,薛孟欣,闵媛,王洋,陶敏,孙燕飞.护理领域人工智能应用态度量表的汉化及信效度检验[J].护理学杂志,2026,41(2):12-15,25

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
历史
  • 收稿日期:2025-06-15
  • 最后修改日期:2025-08-19
  • 录用日期:
  • 在线发布日期: 2026-03-05